Neware CE6000-100V200A Battery Pack Capacity Tester

Original price was: $19,000.00.Current price is: $18,000.00.

Simulation – the Way You Look into Reality

You know battery capacity at at constant current, or power, or load. But the reality is that no the energy is drawn by a constant variable. Your capacity or energy tested under constant conditions can only be a general one, and the cycle life tested such regime can also be largely deviated from reality. To have a better master of reality, simulation is introduced. GSM pulse is of such kind for phone batteries. for EV batteries, Drive Cycle Simulation is used.

CAN Bus Decoder

To handle data exchange with the BMS installed on battery module or pack, Neware CE-6000 is also a CANBUS decoder with decode the signals from BMS. And these valuable data could be applied for further computing like used as stopping or protection conditions.

You can config which frame of CANBus data is for what use manually. Data also can be easily processed with the dbc file imported.

 

Simulation – the Way You Look into Reality

You know battery capacity at at constant current, or power, or load. But the reality is that no the energy is drawn by a constant variable. Your capacity or energy tested under constant conditions can only be a general one, and the cycle life tested such regime can also be largely deviated from reality. To have a better master of reality, simulation is introduced. GSM pulse is of such kind for phone batteries. for EV batteries, Drive Cycle Simulation is used.

 

Driving Cycle Simulation

Driving cycles are used to simulate car’s fuel economy at different operating conditions. There are many driving schedules or driving cycles that are issued by various agencies or institutes. You can visit the EPA (U.S. Environment Protection Agency) website for more: https://www.epa.gov/emission-standards-reference-guide/all-epa-emission-standards. To simulate EV, you need to convert the speed output into the power consumption or regeneration of the energy storage device installed on the vehicle.

Equipment Item Code:  CE-6002n-100V200A-H-Spec.pdf (237 downloads )

1Model
1. Material code CE-6002n-100V200A-H
2Channels information
1. Channels quantity Channels quantity in one unit 2
2. Main channel Channel feature Constant current source and constant voltage source dual closed loop control
  Channel control mode Independent control
  Channel parallel connection Support max 4 channels parallel mode. Pulse and SIM tests will be disabled in channels parallel mode.

 

3Power grid side parameters
1.Input power   AC380V±15%  50/60±5Hz
2.Power factor   ≥99%(Full load)
3.THDi   ≤5%(Full load)
4.Input resistance   ≥1MΩ
5.Input power   47.1KW
6.Input current   71.5A/single
7.Overall system efficiency(Max)   90%
8.Noise   ≤65dB
9.Voltage and current sampling   Four-wire connection(same port for charging and discharging)
10.Power control module type   MOSFET
11.Input power wiring method   Three-phase-five wire system
12.Power input protection   Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti phase absence, etc.
4Functions and performances
1. Voltage Output range Charge:0V~100V
    Discharge:3V~100V
  Min discharge voltage 3V
  Accuracy ±0.02% of FS
  Resolution 24bit
2. Current Output range 1A~200A
  Accuracy(independent range) ±0.05% of FS
  CV cut-off current 200mA
  Resolution 24bit
3. Power Single channel output power 20KW
  Whole machine output power 40KW
4. Time Current response time ≤3ms
  Current conversion time ≤6ms
  Min. step time 0.1s
5. Charge/Discharge modes Charge/Discharge modes CCC, CVC, CC-CVC, CPC
    CCD, CVD, CPD, CRD
  Cut-off condition Voltage, Current, ΔTime, Capacity, -ΔV
6. Simulation Charge Current, Power
  Discharge Current, Power
  Switch Support continuous switching between charge and discharge
  Cut-off condition Time, step line
  Steps file lines 1,000,000
7. Pulse Mode Charge Current ,power
  Discharge Current, Power
  Min pulse 100ms
  Pulse counts Up to 32
  Charge and discharge switch supported
  Cut-off condition Voltage, ΔTime
8. DCIR   DCIR by calculation
9. Safely protection Software protection Power off data protection
    Offline mode function
    Safety protection conditions can be set, including:voltage lower limit ,voltage upper limit ,current lower limit ,current upper limit ,delay time, etc.
  Hardware protection Anti-reverse connection, over-voltage, over-current, over-temperature, etc.
5Data management and analysis
1. Step setting method   Form editing
2. Data report Recording conditions Minimum time interval: 10ms(connected with AUX channel:100ms)
    Minimum voltage interval: 0.2V
    Minimum current interval: 0.4A
  Recording frequency 100Hz(connected with AUX channel:10Hz)
3. Database   MySQL database
4. Data output   Excel, Txt
5. Curve type   Templates available, customization supported
6. Bar code scanning   Support bar-code scanning function
    Management and traceability of historical data
6Communication
1. Host computer communication   TCP/IP protocol
2. Communication port   Ethernet
3. Communication baud rate of the testers   1M
4. Host computer communication baud rate   10M~100M adaptive
5. Communication setup   Set up a LAN(local area network) through switches and routers
6. Communication expansion(optional)   Support CAN, RS485 communication and BMS communication, with DBC configuration function
7Environmental requirements, dimension and weight
1. Operation environment temperature   -10℃~40℃(When the temperature is 25±10℃, the accuracy error caused by temperature change is less than 0.005% of FS per degree)
2. Storage environment temperature   -20℃~50℃
3. Operation environment humidity   ≤70% RH(no moisture condensation)
4. Storage environment humidity   ≤80% RH(no moisture condensation)
5. Dimension W*D*H   600*800*1300(mm)
6. Weight   about 199.1KG
Weight 250 kg
Dimensions 65 × 90 × 140 cm
Brand

Neware

Model

CE-6002n-100V200A-H

Origin

China

Certificate

CE CNAS