Neware BTS4000-5V30A Battery Cell Cycler Testing Equipment

Original price was: $3,600.00.Current price is: $3,300.00.

Data Security

Neware battery testing system utilizes LAN as the main framework to transfer data . This provides the most flexibility and reliablity to your system deployment .

When you look down into Neware battery tester , its unique Middle Machine architecture provides another enhancement layer to the data security issue . Moreover , this MM is an embedded system that allows you run tests even your LAN is down .

Neware Battery Charge and Discharge Testing System , ranging from μA single cell applications up to 1MW packs, is a high precision system designed specifically for testing lithium-ion battery cells, modules, packs and capacitors. It is suitable for product development, quality control , and helpful to characteristic research, cycle life testing, product screening, and quality assessment .

DCIR – Direct Current Internal Resistance

Direct current internal resistance (DCIR) of batteries is the r esistance of current flowing through the battery, with the standard unit of measurement called the ohm.The value of DCIR is not fixed, and varies depending on multiple factors, such as battery materials, electrolyte concentration, temperature, and depth of discharge.

The variation of DCIR has a great influence on battery discharge performance, especially for high power batteries. In general, the better the battery, the lower the internal resistance. Therefore, most battery manufacturers identify DCIR as a key indicator to evaluate battery quality. The method of DCIR measurement is to inject high current into the anodeand cathode of the battery in a short period, and then record the changes of battery voltage and charge/discharge current. To calculate DCIR by Ohm’s Law, voltage variation is divided by current variation.

 

Accurate Timing

Most of us are considering the voltage and current accuracies are the all important factors of a battery tester , but actually timing accuracy is of the same importance .

Capacity or energy is calculated on time basis with the voltage and current measured , thus the timing accuracy will greatly affect the capacity calculated. To a general constant current or other constant testing regimes , this effect may not that easy to be observed .

 

Data Security

Neware battery testing system utilizes LAN as the main framework to transfer data . This provides the most flexibility and reliablity to your system deployment .

When you look down into Neware battery tester , its unique Middle Machine architecture provides another enhancement layer to the data security issue . Moreover , this MM is an embedded system that allows you run tests even your LAN is down .

Equipment Model :BTS-5V30A Battery Testing Equipment     Equipment Item Code: CT-4008-5V30A-NA-Spec.pdf (1331 downloads )

Project index Parameter index
Input Power AC 220V ±10% / 60Hz  Three Phase
resolution AD:16bit;DA:16bit
Input Resistance ≥1MΩ
Input Power 2127W
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode Independent Control
Voltage Per Channel Voltage Range 25mV~5V
Discharge Min Voltage 2.5V
Accuracy ± 0.1% of FS
Stability ± 0.1% of FS
Current Per Channel Current Range 0.15A~30A
Stop Current 0.06A
Accuracy ± 0.1% of FS
Stability ± 0.1% of FS
Power Per Channel Output Power 150W
Stability ± 0.2% of FS
Time Current Response Time 20ms (0-Full Range)
Step Time Range ≤(365*24 )hour/step,

Time Form Support 00:00:00(h、min:s、ms)

Data Recording Record Condition Time△t:100mS
Voltage△U:10mV
Current△I:60mA
Record Frequency 10Hz
Charge Charge Mode Constant Current Charge、Constant Voltage Charge、

Constant Current and Constant Voltage Charge、CPC

End Conditon Voltage、Current、Relative Time、Capacity、-△V
Discharge Discharge Mode CCD、CPD、CRD
End Condition Voltage、Current、Relative Time、Capacity
Pulse charge CCC、CPC
Discharge CCD、CPD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function,Max Support 3 Layers
Protection Software Protection l Power-down Data Protection
l Off-line Testing Function
l Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time
Hardware Protection Additional Anti-reverse Protection Model
Voltage and Current Testing Sample 4-wire connecting
Noise <85dB
Database MySQL Database
A Means of Communication of Upper Machine TCP/IP Protocol
Data Output EXCEL2003/2010、TXT、Graph
Communication Interface Ethernet Port
Per Unit Main Channels No. 8
Dimensions 12U,600*600*740(mm)

Equipment Working Environment

Project index Parameter index
Working Temperature Range 0℃~40℃
Storage Temperature Range -10℃~50℃
Working Environment Relative Humidity Range 30% ~ 80% RH
Storage Environment Relative Humidity Range 30% ~ 90% RH
Dimensions 78 × 78 × 110 cm
Brand

Neware

Model

CT-4008-5V30A-NA

Origin

China

Certificate

CE CNAS