Neware BTS4000-5V100A Prismatic Battery Cell cycle Tester

Original price was: $10,000.00.Current price is: $8,900.00.

BTS4000-5V100A , based on Neware 4th generation testing system , entered into market in 2008 .

BTS4000-5V100A supports some testings as follow: EV battery pulse charge/discharge, DCIR (Direct Current Internal Resistance ) , cycle life and rate.

BTS4000-5V100A mainly applies for institutions , colleges and universities and EV battery manufacturers .

The accuracies of Voltage and/or current may fundamentally affect the results come from a test. That’s why accuracies of voltage and current are so important to a battery tester.

Neware battery testers provide good accuracies both for voltage and current. This ensures you get the most reliable data from your tests.

A measurement system can be accurate but not precise, precise but not accurate, neither, or both. Neware battery testers provide good prrecision meanwhile. To get an overall performance of a measurement system, Measurement system analysis (MSA) is usually introduced for the study.

 

BTS4000-5V100A , based on Neware 4th generation testing system , entered into market in 2008 .

BTS4000-5V100A supports some testings as follow: EV battery pulse charge/discharge, DCIR (Direct Current Internal Resistance ) , cycle life and rate.

BTS4000-5V100A mainly applies for institutions , colleges and universities and EV battery manufacturers .

Equipment Model :BTS-5V100A Battery Testing Equipment     Equipment Item Code: CT-4008-5V100A-NFA-Spec.pdf (128 downloads )

Project index Parameter index
Input Power AC 380V ±10% / 50Hz
resolution AD:16bit;DA:16bit
Input Resistance ≥1MΩ
Input Power 7089W
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode Independent Control
Voltage Per Channel Voltage Range 25mV~5V
Discharge Min Voltage 0V
Accuracy ± 0.1% of FS
Stability ± 0.1% of FS
Current Per Channel Current Range 500mA~100A
Stop current 0.2A
Accuracy ± 0.1% of FS
Stability ± 0.1% of FS
Power Per Channel Output Power 500W
Stability ± 0.2% of FS
Time Current Response Time Less than 20ms (0-Full Range)
Step Time Range ≤(365*24 )hour/step,

Time Form Support 00:00:00(h、min:s、ms)

Data Recording Record Condition Time△t:100ms
Voltage△U:10mV
Current△I:200mA
Record Frequency 10Hz
Charge Charge Mode Constant Current Charge、Constant Voltage Charge、

Constant Current and Constant Voltage Charge、CPC

End Conditon Voltage、Current、Relative Time、Capacity、△V
Discharge Discharge Mode CCD、CPD、CRD
End Condition Voltage、Current、Relative Time、Capacity
Pulse charge CCC
Discharge CCD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function,Max Support 3 Layers
Protection Software Protection l Power-down Data Protection
l Off-line Testing Function
l Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time
Hardware Protection Additional Anti-reverse Protection Model
Voltage and Current Testing Sample 4-wire connecting
Noise <85dB
Database MySQL Database
A Means of Communication of Upper Machine TCP/IP Protocol
Data Output EXCEL2003/2010、TXT
Communication Interface Ethernet Port
Per Unit Main Channels No. 8
Dimensions 24U, 600*600*1260(mm)

Equipment Working Environment

Project index Parameter index
Working Temperature Range 0℃~40℃
Storage Temperature Range -10℃~50℃
Working Environment Relative Humidity Range ≤70% RH
Storage Environment Relative Humidity Range ≤80% RH
Weight 250 kg
Dimensions 65 × 65 × 135 cm
Brand

Neware

Model

CT-4008-5V100A-NFA

Origin

China

Certificate

CE CNAS