Neware Battery Test Hight Temperature Chamber Explosion Proof

Original price was: $7,500.00.Current price is: $6,500.00.

Neware environmental test chamber (also knows as high and low temperature box, high temperature box, incubator and explosion proof box) is researched and produced by Neware for battery testing in new energy industry, which can provide the required high temperature, low temperature and constant temperature environment for battery charge, discharge and safety performance testing, and it can simulate climate environment for researchers to do tests in lab. Neware environmental test chamber is also a reliable equipment for all companies such as electronics, electricians, instruments, materials and semiconductor, as well as for departments such as schools, medicine, chemical, environmental protection, agriculture, livestock and aquatic products, etc.

Environmental Test Chamber

Neware environmental test chamber aims to test battery performance under temperature by simulating harsh climate conditions.  it can analyze and evaluate whether the battery can meet the required international standard and provides a good reference in the product R&D stage. What’s more,  it’s widely applied to Electronics, Telecommunication, Automobile, Packaging, Aerospace, Electric products, Pharmaceuticals industry, etc.

Neware environmental test chamber (also knows as high and low temperature box, high temperature box, incubator and explosion proof box) is researched and produced by Neware for battery testing in new energy industry, which can provide the required high temperature, low temperature and constant temperature environment for battery charge, discharge and safety performance testing, and it can simulate climate environment for researchers to do tests in lab. Neware environmental test chamber is also a reliable equipment for all companies such as electronics, electricians, instruments, materials and semiconductor, as well as for departments such as schools, medicine, chemical, environmental protection, agriculture, livestock and aquatic products, etc.

Product: Single-layer Flameproof High Temperature Test Chamber: MGW-150-B-220V-Chamber-Spec.pdf (63 downloads )

1.1 Model MGW-150-B-220V
1.2Model nomenclature
MGW 150 2 B F 380V B
         
High temperature test box series
Nominal inner volume of single-layer cabinet: 150L (other numbers are analogous)
2: 2-layer box type (1 layer is not indicated, other numbers are analogous)
B: Flameproof (no flameproof function is not indicated)
F: Automatic fire extinguishing function (no fire extinguishing function is not indicated)
380V: Equipment voltage 380V (default 380V is omitted and not indicated, other voltages are analogous)
B: The product iterative update version number, which is A, B, C…, the default A does not mean

 

1. Applications Electronics, electricians, instruments, materials, semiconductors and other manufacturers conduct drying, baking and heat treatment tests on non-flammable and non-explosive items.

Drying, baking, disinfection, heat preservation and heat treatment tests of non-flammable and non-explosive items are carried out by schools, medicine, chemical industry and other units for scientific research.

Drying and aging in the production process of LEDs, LCDs, quartz crystals, capacitors, resistors and other products that require high constant temperature accuracy and reliability.

2. Specimen Limit This test equipment prohibits:

Testing or storage of flammable, explosive and volatile material samples;

Testing or storage of samples of corrosive substances;

Testing or storage of biological samples;

Testing or storage of samples of strong electromagnetic emission sources;

Testing and storage of radioactive material samples;

Testing and storage of samples of highly toxic substances;

Testing or storage of samples that may produce the above substances or objects during testing or storage.

3. Volume, Size
4.1 Nominal internal volume 150L
4.2 Inner box size W500 mm×D500 mm×H600 mm
4.3 Dimensions W750 mm×D1100 mm×H1350 mm(no protrusions)
4.4 Equipment net weight About 190 Kgs
4. Performance
5.1 Environmental conditions The ambient temperature is +25℃, the relative humidity is less than or equal to 85%, and there is no sample in the test box (no load)
5.2 Temperature range (ambient temperature +15℃)~150℃
5.3 Temperature fluctuation ≤1℃(No-load, when the temperature is stable)
5.4 Temperature deviation ±2.0℃(No-load, when the temperature is stable)
5.5 Heating time (ambient temperature +15℃)→+150℃ ≤40 min
5. Structure
6.1 Insulation envelope Outer wall material: high-quality cold-rolled steel plate, surface sprayed and painted;

Inner wall material: stainless steel plate;

Box insulation material: glass wool (insulation thickness 100mm).

6.2 Air conditioning channel Centrifugal fans, heaters, etc.
6.3 Test box standard configuration Lead hole (single layer, can be added): φ100mm /1

(with soft rubber stopper, on the left side of the box)

Casters: 4

Cell tray (single layer, can be added): 2 layers of high temperature resistant electrical insulation cell tray, load-bearing (uniform distribution): 10kg/layer (the cumulative total load of samples in the box does not exceed: 30kg)

Observation window (single layer):

multi-layer insulating glass

Observation window viewing range:

230 × 270 mm (width × height)

Lights: 1

Door: Single hinged door (left hinge, right handle)

 

6.4 Control Panel Controller, over-temperature protection setter, buzzer, etc. (set on the right side of the box)
6.5 Power distribution control cabinet Main power leakage circuit breaker, AC contactor, solid state relay, etc.
6.6 Heater Finned heating tube (explosion-proof type)

Heater control mode: non-contact equal period pulse width adjustment, SSR (solid state relay)

6.7 Explosion-proof pressure relief port It is located on the left side of the box and automatically opens when the test space pressure exceeds the set pressure
6. Electrical control system
7.1 Controller model Professional temperature controller
7.2 Monitor HD color LCD touch screen
7.3 Operation mode Program method, fixed value method
7.4 How to set Color touch human-computer interaction, Chinese/English interface
7.5 Way to control Anti-windup PID

BTC balance temperature control method

7.6 Temperature measurement method  Class A armored PT100 sensor
7.7 Display accuracy Temperature: 0.01℃; Time: 1min
7.8 Over temperature protection Independent over-temperature protector, when the working room temperature exceeds the temperature set by this protection device, it will protect the shutdown and send an alarm signal
7. Safety protection device
8.1 Test box Leakage protection, short circuit protection, extreme high temperature protection, abnormal protection of circulating fan, etc.
8.2 Smoke alarm Equipped with a smoke alarm, it will automatically alarm when there is smoke
8.3 Smoke exhaust device When the smoke alarm detects that the smoke concentration exceeds the standard, it will start the smoke exhaust fan
8. Other configuration
9.1 Power cable 1 five-core (three-phase four-wire + protective ground wire) cable (specific specifications are selected according to contract requirements)
9.2 Main power leakage circuit breaker Three-phase four-wire + protective ground wire
9. Transportation   The test box is integral and transported as a whole
Size Maximum shipping dimensions (without packaging): “See 4.3 Dimensions”
10. Conditions of Use   The following conditions are guaranteed by the user (the installation of the power supply line of the equipment is the responsibility of the user)
11.1 Installation site The ground is flat, in line with GB50209-2002 specification: flatness ≤ 5mm/2m

Good ventilation, no strong vibration around the device, no strong electromagnetic field around the device

No flammable, explosive, corrosive substances and dust around the equipment

Appropriate space for use and maintenance should be left around the equipment (for ventilation and convenience of operation and maintenance, there should be at least one person passing space around the equipment, that is, ≥ 600 mm; there should be a door that can be opened and closed normally at the equipment unpacking door. space, and there should be no other objects in front of the door of the equipment box, so as not to be scalded by the hot air discharged when the door is opened)

11.2 Environmental conditions Temperature: 5℃~35℃; Relative Humidity: ≤85%; Air Pressure: 86kPa~106kPa
11.3 Power supply conditions

 

 

Power supply

 

 

Power

Maximum current

AC(220±22)V (50±0.5)Hz Single-phase + protective earth wire

The grounding resistance of the protective ground wire is less than 4Ω

 

 

The user is required to configure an air or power switch of the corresponding capacity for the equipment at the installation site, and this switch must be used independently for the equipment

3kW

15A

11.4 Others Opening the door of the test box during the test will cause temperature fluctuations in the box
Weight 210 kg
Dimensions 80 × 115 × 140 cm
Brand

Neware

Model

MGW-150-B-220V

Origin

China

Certificate

CE